SAVED COST PLANS · LOCAL NUMERICAL COMPARISON

Two saved cost plans, one numerical job

The complete objective scores tie.

One identical original numerical job and row prices. Lower feasible cost/raw/bar objective refutes the higher score, not proof that the preferred layout is globally best. Offcut thresholds are separate; no physical suitability, invoice, currency conversion, billing or realized saving is established.

No native run, payment or revenue is reported by this local comparison.

Verified objective scores

PlanAmountRaw length (mm)Bars
A2202
B2202

B minus A

Supplied amount: 0 cost units · raw length: 0 mm · bars: 0.

Best compared score, full-objective status: not_assessed.

Stock rowLengthAmount/barUsed AUsed BAmount B − A
1101220

Plan A: cost optimum refuted: false; full objective refuted: false. Source cost/full claims refuted: false/false. Independent minimum proofs remain separate below.

Plan B: cost optimum refuted: false; full objective refuted: false. Source cost/full claims refuted: false/false. Independent minimum proofs remain separate below.

Offcut distributions remain separate

Plan A: 1 × 0 mm below the threshold or zero; 1 × 4 mm above the reusable threshold.

Plan B: 2 × 2 mm below the threshold or zero.

Plan A

Linear Cut Planner / 1D stock allocation

Saved-file numerical check

This record checks the supplied original input and report; it does not run the paid planner. Source flags remain separate from independent proof.

Source flags: {"costOptimalityProven": false, "infeasibilityProven": false, "optimalityProven": false}.

Cost proof: unassessed or incomplete; full objective proof: unassessed or incomplete.

Keep the original files. Hashes bind these bytes, not who created them, the physical material or a real saving.

inputSha256: 36ef79862b5607837673390c51de142328d034855514667c65851f1f946a33cd

reportSha256: 8fa53079511a4ccfd98aef9f8e7b35a85d40c9389a0cbd21ffce5d96903a9fab

cutsSha256: dfea03343dedf421358d2422790c3b435d8707796bb1536144f4791cae21d67c

stockSha256: 2622a7086e936a252859a72cdedada30131ef4e52934449e91691d104a148045

Checked saved cost layout

All dimensions in mm. One material and cross-section.

Verified feasible cost layout; minimum unproven

Objective: supplied acquisition amount, then raw stock length, then bar count.

Supplied amount 2 cost units. Verified cost lower bound 0 cost units; a lower bound alone need not be attainable.

not independently established. Full objective: not independently established.

Parts placed4
Bars used2
Cutting patterns2
Part yield80.0%

20 stock = 16 parts + 0 kerf + 0 trim + 4 reusable offcut + 0 scrap offcut (mm).

Supplied stock acquisition amounts

Explicit supplied whole-bar amounts in one common cost unit; no conversion or physical saving is assessed.

Stock rowLength (mm)Available barsAmount per barBars usedSubtotal
1102122

Complete plan total: 2 cost units.

Parts to produce

  • P-1 · 6 mm × 1 (row 1)
  • P-2 · 4 mm × 2 (row 2)
  • P-3 · 2 mm × 1 (row 3)

Stock allocation

Stock row 1 · 10 mm · 2 used / 2 available · 0 remaining

Kerf 0 · start trim 0 · end trim 0 · reusable offcut ≥ 3 mm.

Part Kerf Offcut Trim. Diagram is schematic; use the numeric table.

1 barPattern 1 · 10 mm

Stock row 1 · bar 1. Cut sequence below is for this bar.

Read left to right. Diagram numbers match Sequence below; narrow segments may be unlabelled.

SequencePart codeLengthStartEndKerf after
1P-16060
2P-246100

Offcut per bar: 0 mm · below threshold or zero.

1 barPattern 2 · 10 mm

Stock row 1 · bar 2. Cut sequence below is for this bar.

Read left to right. Diagram numbers match Sequence below; narrow segments may be unlabelled.

SequencePart codeLengthStartEndKerf after
1P-24040
2P-32460

Offcut per bar: 4 mm · reusable by length threshold.

Model and limits

  • Same original numerical job; all complete coordinates and balances checked.
  • One identical original numerical job and row prices. Lower feasible cost/raw/bar objective refutes the higher score, not proof that the preferred layout is globally best. Offcut thresholds are separate; no physical suitability, invoice, currency conversion, billing or realized saving is established.
Linear Cut Planner 2.0.0 · No machine code. Review measurements and machine allowances before cutting. Print or save this page using your browser.

Plan B

Linear Cut Planner / 1D stock allocation

Saved-file numerical check

This record checks the supplied original input and report; it does not run the paid planner. Source flags remain separate from independent proof.

Source flags: {"costOptimalityProven": false, "infeasibilityProven": false, "optimalityProven": false}.

Cost proof: unassessed or incomplete; full objective proof: unassessed or incomplete.

Keep the original files. Hashes bind these bytes, not who created them, the physical material or a real saving.

inputSha256: 36ef79862b5607837673390c51de142328d034855514667c65851f1f946a33cd

reportSha256: 8aaa5991890616f832b7694f07fdfc8d74bc8a35a368b35d32c9703a276cdf5f

cutsSha256: d228139aa86dafd9c2a6f570aa03a512404fccbed125040bc95e47f35aba872f

stockSha256: b3ee46fd53ba58bb76cdb05cfa38f08fe95a9e5fbf0e3713b9866c635c52af11

Checked saved cost layout

All dimensions in mm. One material and cross-section.

Verified feasible cost layout; minimum unproven

Objective: supplied acquisition amount, then raw stock length, then bar count.

Supplied amount 2 cost units. Verified cost lower bound 0 cost units; a lower bound alone need not be attainable.

not independently established. Full objective: not independently established.

Parts placed4
Bars used2
Cutting patterns2
Part yield80.0%

20 stock = 16 parts + 0 kerf + 0 trim + 0 reusable offcut + 4 scrap offcut (mm).

Supplied stock acquisition amounts

Explicit supplied whole-bar amounts in one common cost unit; no conversion or physical saving is assessed.

Stock rowLength (mm)Available barsAmount per barBars usedSubtotal
1102122

Complete plan total: 2 cost units.

Parts to produce

  • P-1 · 6 mm × 1 (row 1)
  • P-2 · 4 mm × 2 (row 2)
  • P-3 · 2 mm × 1 (row 3)

Stock allocation

Stock row 1 · 10 mm · 2 used / 2 available · 0 remaining

Kerf 0 · start trim 0 · end trim 0 · reusable offcut ≥ 3 mm.

Part Kerf Offcut Trim. Diagram is schematic; use the numeric table.

1 barPattern 1 · 10 mm

Stock row 1 · bar 1. Cut sequence below is for this bar.

Read left to right. Diagram numbers match Sequence below; narrow segments may be unlabelled.

SequencePart codeLengthStartEndKerf after
1P-16060
2P-32680

Offcut per bar: 2 mm · below threshold or zero.

1 barPattern 2 · 10 mm

Stock row 1 · bar 2. Cut sequence below is for this bar.

Read left to right. Diagram numbers match Sequence below; narrow segments may be unlabelled.

SequencePart codeLengthStartEndKerf after
1P-24040
2P-24480

Offcut per bar: 2 mm · below threshold or zero.

Model and limits

  • Same original numerical job; all complete coordinates and balances checked.
  • One identical original numerical job and row prices. Lower feasible cost/raw/bar objective refutes the higher score, not proof that the preferred layout is globally best. Offcut thresholds are separate; no physical suitability, invoice, currency conversion, billing or realized saving is established.