Linear Cut Planner / 1D stock allocation
Saved-file numerical check
This record checks the supplied original input and report; it does not run the paid planner. Source flags remain separate from independent proof.
Source flags: {"costOptimalityProven": true, "infeasibilityProven": false, "optimalityProven": true}.
Cost proof: completed; full objective proof: completed.
Keep the original files. Hashes bind these bytes, not who created them, the physical material or a real saving.
inputSha256: 2d0731e2bd1b31fd400c8cadf0144f6482e380fe930f4c5f4fd69ac2bb315a1f
reportSha256: 095806152696b65933533b4741da847c9527200deea4062640f3195633ad91ae
Checked saved cost layout
All dimensions in in. One material and cross-section.
Objective: supplied acquisition amount, then raw stock length, then bar count.
Supplied amount 0 cost units. Verified cost lower bound 0 cost units; a lower bound alone need not be attainable.
independent numerical proof completed. Full objective: independent objective proof completed.
1.065 stock = 1 parts + 0.035 kerf + 0.03 trim + 0 reusable offcut + 0 scrap offcut (in).
Supplied stock acquisition amounts
Supplied whole-bar acquisition amounts in one common cost unit; no currency conversion, tax, labour, residual value or realized saving is assessed.
| Stock row | Length (in) | Available bars | Amount per bar | Bars used | Subtotal |
|---|---|---|---|---|---|
| 1 | 1.065 | 1 | 0 | 1 | 0 |
| 2 | 0.031 | 1 | 0.02 | 0 | 0 |
Complete plan total: 0 cost units.
Parts to produce
- P-1 · 0.125 in × 4 (row 1)
- P-2 · 0.125 in × 4 (row 2)
Stock allocation
Kerf 0.005 · start trim 0.01 · end trim 0.02 · reusable offcut ≥ 1 in.
Part Kerf Offcut Trim. Diagram is schematic; use the numeric table.
Model and limits
- One identical material and cross-section per run; straight square cuts only.
- End trim is total reserved loss, including any trim-cut kerf. No extra trim kerf is added.
- One full kerf follows each part unless it ends exactly at the trimmed stock end.
- A positive end sliver smaller than a full kerf is conservatively refused.
- Coordinates are from the original stock start; end is the finished part edge, not a saw centerline.
- Offcuts are classified by supplied minimum length only; material suitability is not checked.
- No defects, tolerances, clamping allowance, miter angles, machine code or structural checks.
- Feasibility uses the supplied dimensions. Review measurements and machine allowances before use.
- Supplied whole-bar acquisition amounts in one common cost unit; no currency conversion, tax, labour, residual value or realized saving is assessed.